Chapter Techno-Economic Optimization and Benchmarking of a Solar-Only Powered Combined Cycle with High-Temperature TES Upstream the Gas Turbine (Record no. 2987642)

MARC details
000 -LEADER
fixed length control field 03227naaaa2200361uu 4500
001 - CONTROL NUMBER
control field https://directory.doabooks.org/handle/20.500.12854/70423
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220714165832.0
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number intechopen.90410
024 7# - OTHER STANDARD IDENTIFIER
Standard number or code 10.5772/intechopen.90410
Terms of availability doi
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title English
042 ## - AUTHENTICATION CODE
Authentication code dc
072 #7 - SUBJECT CATEGORY CODE
Subject category code TBC
Source bicssc
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Valentin, Benoît
Relator code auth
9 (RLIN) 1583041
245 10 - TITLE STATEMENT
Title Chapter Techno-Economic Optimization and Benchmarking of a Solar-Only Powered Combined Cycle with High-Temperature TES Upstream the Gas Turbine
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Name of publisher, distributor, etc InTechOpen
Date of publication, distribution, etc 2019
506 0# - RESTRICTIONS ON ACCESS NOTE
Terms governing access Open Access
Source of term star
Standardized terminology for access restriction Unrestricted online access
520 ## - SUMMARY, ETC.
Summary, etc This work presents a techno-economic parametric study of an innovative central receiver solar thermal power plant layout that applies the combined cycle (CC) as thermodynamic power cycle and a multi-tower solar field configuration together with open volumetric air receivers (OVARs). The topping gas turbine (GT) is powered by an air-air heat exchanger (two heat exchanger trains in the case of reheat). In order to provide dispatchability, a high-temperature thermocline TES system is placed upstream the gas turbine. The aim is threefold, (i) investigating whether the multi-tower concept has a techno-economic advantage with respect to conventional single-tower central receiver plants, (ii) indicating the techno-economic optimum power plant configuration, and (iii) benchmarking the techno-economic optimum of the CC plant against that of a conventional single-cycle Rankine steam plant with the same receiver and TES technology. It is concluded that the multi-tower configuration has a techno-economic advantage with respect to the conventional single-tower arrangement above a total nominal solar power level of about 150 MW. However, the benchmarking of the CC against a Rankine single-cycle power plant layout shows that the CC configuration has despite its higher solar-to-electric conversion efficiency a higher LCOE. The gain in electricity yield is not enough to outweigh the higher investment costs of the more complex CC plant layout.
540 ## - TERMS GOVERNING USE AND REPRODUCTION NOTE
Terms governing use and reproduction Creative Commons
-- https://creativecommons.org/licenses/by/3.0/
-- cc
-- https://creativecommons.org/licenses/by/3.0/
546 ## - LANGUAGE NOTE
Language note English
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Engineering: general
Source of heading or term bicssc
9 (RLIN) 928610
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term concentrated solar power, solar combined cycle, multi-tower central receiver, open volumetric air receiver (OVAR)
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Zaversky, Fritz
Relator code auth
9 (RLIN) 1583042
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Les, Iñigo
Relator code auth
9 (RLIN) 1583043
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Berard, Flavien
Relator code auth
9 (RLIN) 1583044
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Brau, Jean-Florian
Relator code auth
9 (RLIN) 1583045
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Sánchez, Marcelino
Relator code auth
9 (RLIN) 1583046
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name McGuire, Jonathon
Relator code auth
9 (RLIN) 1583047
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Siros, Frédéric
Relator code auth
9 (RLIN) 1583048
773 10 - HOST ITEM ENTRY
Host Biblionumber OAPEN Library ID: ONIX_20210602_10.5772/intechopen.90410_416
Control subfield nnaa
856 40 - ELECTRONIC LOCATION AND ACCESS
Host name www.oapen.org
Uniform Resource Identifier <a href="https://library.oapen.org/bitstream/20.500.12657/49302/1/70392.pdf">https://library.oapen.org/bitstream/20.500.12657/49302/1/70392.pdf</a>
-- 0
Public note DOAB: download the publication
856 40 - ELECTRONIC LOCATION AND ACCESS
Host name www.oapen.org
Uniform Resource Identifier <a href="https://library.oapen.org/bitstream/20.500.12657/49302/1/70392.pdf">https://library.oapen.org/bitstream/20.500.12657/49302/1/70392.pdf</a>
-- 0
Public note DOAB: download the publication
856 40 - ELECTRONIC LOCATION AND ACCESS
Host name www.oapen.org
Uniform Resource Identifier <a href="https://directory.doabooks.org/handle/20.500.12854/70423">https://directory.doabooks.org/handle/20.500.12854/70423</a>
-- 0
Public note DOAB: description of the publication
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Date last seen Price effective from Koha item type
        E-Books Open Access OPJGU Sonepat- Campus OPJGU Sonepat- Campus 14/07/2022   14/07/2022 14/07/2022 Electronic-Books

O.P. Jindal Global University, Sonepat-Narela Road, Sonepat, Haryana (India) - 131001

Send your feedback to glus@jgu.edu.in

Hosted, Implemented & Customized by: BestBookBuddies   |   Maintained by: Global Library