MARC details
000 -LEADER |
fixed length control field |
03227naaaa2200361uu 4500 |
001 - CONTROL NUMBER |
control field |
https://directory.doabooks.org/handle/20.500.12854/70423 |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20220714165832.0 |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
International Standard Book Number |
intechopen.90410 |
024 7# - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.5772/intechopen.90410 |
Terms of availability |
doi |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
English |
042 ## - AUTHENTICATION CODE |
Authentication code |
dc |
072 #7 - SUBJECT CATEGORY CODE |
Subject category code |
TBC |
Source |
bicssc |
100 1# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Valentin, Benoît |
Relator code |
auth |
9 (RLIN) |
1583041 |
245 10 - TITLE STATEMENT |
Title |
Chapter Techno-Economic Optimization and Benchmarking of a Solar-Only Powered Combined Cycle with High-Temperature TES Upstream the Gas Turbine |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) |
Name of publisher, distributor, etc |
InTechOpen |
Date of publication, distribution, etc |
2019 |
506 0# - RESTRICTIONS ON ACCESS NOTE |
Terms governing access |
Open Access |
Source of term |
star |
Standardized terminology for access restriction |
Unrestricted online access |
520 ## - SUMMARY, ETC. |
Summary, etc |
This work presents a techno-economic parametric study of an innovative central receiver solar thermal power plant layout that applies the combined cycle (CC) as thermodynamic power cycle and a multi-tower solar field configuration together with open volumetric air receivers (OVARs). The topping gas turbine (GT) is powered by an air-air heat exchanger (two heat exchanger trains in the case of reheat). In order to provide dispatchability, a high-temperature thermocline TES system is placed upstream the gas turbine. The aim is threefold, (i) investigating whether the multi-tower concept has a techno-economic advantage with respect to conventional single-tower central receiver plants, (ii) indicating the techno-economic optimum power plant configuration, and (iii) benchmarking the techno-economic optimum of the CC plant against that of a conventional single-cycle Rankine steam plant with the same receiver and TES technology. It is concluded that the multi-tower configuration has a techno-economic advantage with respect to the conventional single-tower arrangement above a total nominal solar power level of about 150 MW. However, the benchmarking of the CC against a Rankine single-cycle power plant layout shows that the CC configuration has despite its higher solar-to-electric conversion efficiency a higher LCOE. The gain in electricity yield is not enough to outweigh the higher investment costs of the more complex CC plant layout. |
540 ## - TERMS GOVERNING USE AND REPRODUCTION NOTE |
Terms governing use and reproduction |
Creative Commons |
-- |
https://creativecommons.org/licenses/by/3.0/ |
-- |
cc |
-- |
https://creativecommons.org/licenses/by/3.0/ |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name as entry element |
Engineering: general |
Source of heading or term |
bicssc |
9 (RLIN) |
928610 |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
concentrated solar power, solar combined cycle, multi-tower central receiver, open volumetric air receiver (OVAR) |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Zaversky, Fritz |
Relator code |
auth |
9 (RLIN) |
1583042 |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Les, Iñigo |
Relator code |
auth |
9 (RLIN) |
1583043 |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Berard, Flavien |
Relator code |
auth |
9 (RLIN) |
1583044 |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Brau, Jean-Florian |
Relator code |
auth |
9 (RLIN) |
1583045 |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Sánchez, Marcelino |
Relator code |
auth |
9 (RLIN) |
1583046 |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
McGuire, Jonathon |
Relator code |
auth |
9 (RLIN) |
1583047 |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Siros, Frédéric |
Relator code |
auth |
9 (RLIN) |
1583048 |
773 10 - HOST ITEM ENTRY |
Host Biblionumber |
OAPEN Library ID: ONIX_20210602_10.5772/intechopen.90410_416 |
Control subfield |
nnaa |
856 40 - ELECTRONIC LOCATION AND ACCESS |
Host name |
www.oapen.org |
Uniform Resource Identifier |
<a href="https://library.oapen.org/bitstream/20.500.12657/49302/1/70392.pdf">https://library.oapen.org/bitstream/20.500.12657/49302/1/70392.pdf</a> |
-- |
0 |
Public note |
DOAB: download the publication |
856 40 - ELECTRONIC LOCATION AND ACCESS |
Host name |
www.oapen.org |
Uniform Resource Identifier |
<a href="https://library.oapen.org/bitstream/20.500.12657/49302/1/70392.pdf">https://library.oapen.org/bitstream/20.500.12657/49302/1/70392.pdf</a> |
-- |
0 |
Public note |
DOAB: download the publication |
856 40 - ELECTRONIC LOCATION AND ACCESS |
Host name |
www.oapen.org |
Uniform Resource Identifier |
<a href="https://directory.doabooks.org/handle/20.500.12854/70423">https://directory.doabooks.org/handle/20.500.12854/70423</a> |
-- |
0 |
Public note |
DOAB: description of the publication |